Configuring the Colorociter CS-1 for Use with Ethernet Interface
| Article Number 420112 Last Edited
Keywords
|
Platforms/Versions Color Finesse 2.1.5 or later on Macintosh OS X and Colorociter CS-1 Colorist’s Control Surface with Ethernet interface. ProblemIn order for Color Finesse to communicate with the Colorociter control surface both must be properly configured with matching network settings. Solution Start by configuring the Colorociter for your network settings. You will need to know the IP address to be used by the Colorociter as well as the subnet mask.The Colorociter does not support DHCP so you must manually assign it a fixed IP address. If you have a network administrator they will be able to supply you with the required information. If you do not have an administrator you will need to determine your current network settings and assign a new IP address to the Colorociter. Once you have the subnet mask and IP address you can configure the Colorociter. Turn on the power to the Colorociter and wait for the initialization sequence to end. When you see the text “Synthetic Aperture Colorociter” in the display, enter configuration mode by simultaneously pressing both the Page 4 and the Reset buttons on the Colorociter. You should now see a display that looks like this: Once you have set the desired subnet mask, press the Reset button to save your settings. Now set the IP address by entering configuration mode again by simultaneously pressing both the Page 4 and the Reset buttons on the Colorociter. Then press Page 7 to enter IP setup mode where you’ll see a display like this: Once you have set the desired IP address and port, press the Reset button to save your settings. To ensure that the settings are active in the Colorociter after they have been changed, perform a hard reset by turning off the power to the Colorociter, counting to five, and turning the power back on. That completes the configuration of the Colorociter. You must now configure Color Finesse to have matching settings. Start the Color Finesse user interface and select Preferences from the application menu. Select the Control Surface tab and you’ll see a pane which looks like this: To test the Colorociter, quit from the Color Finesse user interface. If you are using the plug-in version of Color Finesse, select Quit from the File menu rather than clicking OK as you normally would. Restart the Color Finesse user interface and the Colorociter should be initialized and be ready to use. If Color Finesse is unable to communicate with the Colorociter for some reason, there may be a delay of 2-3 minutes while the connection attempt times out. (This lengthy "hang" is imposed by the operating system, not Color Finesse.) For tips on troubleshooting a communications problem, see the Knowledge Base article Colorociter CS-1 with Ethernet Interface is Not Responding.
Related Documents Colorociter CS-1 Colorist’s Control Surface User’s Guide |
|
About Us | What's New | Press Room | User Forum | Register a Product |
|
Copyright © 1996-2007, Synthetic Aperture. All rights reserved. Color Finesse is a registered trademark, and Synthetic Aperture, Video Finesse, Echo Fire, Test Gear, Test Pattern Maker, Colorociter, and LiveFire are trademarks of Synthetic Aperture. All other trademarks are the property of their respective owners. Comments, corrections, and suggestions should be sent via our feedback form. This page was last updated Sunday, January 28, 2007. |